Extension Gerätehersteller auf Serienebene
Diese Erweiterung ermöglicht das Anlegen des Modelnamens und des Herstellers des Bilderzeugendes Gerätes auf Serienebene.
Relevante DICOM-Tags:
Hersteller [(0008,0070) Manufacturer]
Manufacturer's Model Name [(0008,1090) manufacturerModelName]
| Name | Status | Version | Canonical | Basis |
|---|---|---|---|---|
| MII_EX_Bildgebung_Geraete_Hersteller | active | 2025.0.0-ballot | https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller | http://hl7.org/fhir/StructureDefinition/Extension |
Inhalt
| MII_EX_Bildgebung_Geraete_Hersteller (Extension) | I | Extension | |
| id | 0..1 | string | |
| extension | I | 0..* | Extension |
| manufacturer | S I | 0..1 | Extension |
| id | 0..1 | string | |
| extension | I | 0..0 | Extension |
| url | 1..1 | uriFixed Value | |
| value[x] | 0..1 | ||
| valueString | string | ||
| manufacturerModelName | S I | 0..1 | Extension |
| id | 0..1 | string | |
| extension | I | 0..0 | Extension |
| url | 1..1 | uriFixed Value | |
| value[x] | 0..1 | ||
| valueString | string | ||
| url | 1..1 | uriFixed Value | |
| value[x] | 0..0 |
Die Extension ermöglicht es, Informationen zum verwendeten Gerät und dessen Hersteller auf Serien-Ebene anzugeben. |
| Feldname |
|---|
| Extension.extension:manufacturer |
| Extension.extension:manufacturerModelName |
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="mii-ex-bildgebung-geraet-hersteller" /> <url value="https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" /> <version value="2025.0.0-ballot" /> <name value="MII_EX_Bildgebung_Geraete_Hersteller"> <extension url="http://hl7.org/fhir/StructureDefinition/translation"> <extension url="lang"> <valueCode value="en-US" /> </extension> <extension url="content"> <valueString value="MII_EX_Imaging_Device_Manufacturer" /> </extension> </extension> </name> <title value="MII EX Bildgebung Gerät und Hersteller"> <extension url="http://hl7.org/fhir/StructureDefinition/translation"> <extension url="lang"> <valueCode value="en-US" /> </extension> <extension url="content"> <valueString value="MII EX Imaging Device and Manufacturer" /> </extension> </extension> </title> <status value="active" /> <experimental value="false" /> <publisher value="Medizininformatik Initiative" /> <contact> <telecom> <system value="url" /> <value value="https://www.medizininformatik-initiative.de" /> </telecom> </contact> <description value="Die Extension ermöglicht es, Informationen zum verwendeten Gerät und dessen Hersteller auf Serien-Ebene anzugeben."> <extension url="http://hl7.org/fhir/StructureDefinition/translation"> <extension url="lang"> <valueCode value="en-US" /> </extension> <extension url="content"> <valueString value="The extension allows specifying information about the device used and its manufacturer at the series level." /> </extension> </extension> </description> <fhirVersion value="4.0.1" /> <kind value="complex-type" /> <abstract value="false" /> <context> <type value="element" /> <expression value="ImagingStudy.series" /> </context> <type value="Extension" /> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Extension" /> <derivation value="constraint" /> <differential> <element id="Extension.extension:manufacturer"> <path value="Extension.extension" /> <sliceName value="manufacturer" /> <min value="0" /> <max value="1" /> <mustSupport value="true" /> </element> <element id="Extension.extension:manufacturer.extension"> <path value="Extension.extension.extension" /> <max value="0" /> </element> <element id="Extension.extension:manufacturer.url"> <path value="Extension.extension.url" /> <fixedUri value="manufacturer" /> </element> <element id="Extension.extension:manufacturer.value[x]"> <path value="Extension.extension.value[x]" /> <type> <code value="string" /> </type> </element> <element id="Extension.extension:manufacturerModelName"> <path value="Extension.extension" /> <sliceName value="manufacturerModelName" /> <min value="0" /> <max value="1" /> <mustSupport value="true" /> </element> <element id="Extension.extension:manufacturerModelName.extension"> <path value="Extension.extension.extension" /> <max value="0" /> </element> <element id="Extension.extension:manufacturerModelName.url"> <path value="Extension.extension.url" /> <fixedUri value="manufacturerModelName" /> </element> <element id="Extension.extension:manufacturerModelName.value[x]"> <path value="Extension.extension.value[x]" /> <type> <code value="string" /> </type> </element> <element id="Extension.url"> <path value="Extension.url" /> <fixedUri value="https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" /> </element> <element id="Extension.value[x]"> <path value="Extension.value[x]" /> <max value="0" /> </element> </differential> </StructureDefinition>
{ "resourceType": "StructureDefinition", "id": "mii-ex-bildgebung-geraet-hersteller", "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller", "version": "2025.0.0-ballot", "name": "MII_EX_Bildgebung_Geraete_Hersteller", "_name": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/translation", "extension": [ { "url": "lang", "valueCode": "en-US" }, { "url": "content", "valueString": "MII_EX_Imaging_Device_Manufacturer" } ] } ] }, "title": "MII EX Bildgebung Gerät und Hersteller", "_title": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/translation", "extension": [ { "url": "lang", "valueCode": "en-US" }, { "url": "content", "valueString": "MII EX Imaging Device and Manufacturer" } ] } ] }, "status": "active", "experimental": false, "publisher": "Medizininformatik Initiative", "contact": [ { "telecom": [ { "system": "url", "value": "https://www.medizininformatik-initiative.de" } ] } ], "description": "Die Extension ermöglicht es, Informationen zum verwendeten Gerät und dessen Hersteller auf Serien-Ebene anzugeben.", "_description": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/translation", "extension": [ { "url": "lang", "valueCode": "en-US" }, { "url": "content", "valueString": "The extension allows specifying information about the device used and its manufacturer at the series level." } ] } ] }, "fhirVersion": "4.0.1", "kind": "complex-type", "abstract": false, "context": [ { "type": "element", "expression": "ImagingStudy.series" } ], "type": "Extension", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension", "derivation": "constraint", "differential": { "element": [ { "id": "Extension.extension:manufacturer", "path": "Extension.extension", "sliceName": "manufacturer", "min": 0, "max": "1", "mustSupport": true }, { "id": "Extension.extension:manufacturer.extension", "path": "Extension.extension.extension", "max": "0" }, { "id": "Extension.extension:manufacturer.url", "path": "Extension.extension.url", "fixedUri": "manufacturer" }, { "id": "Extension.extension:manufacturer.value[x]", "path": "Extension.extension.value[x]", "type": [ { "code": "string" } ] }, { "id": "Extension.extension:manufacturerModelName", "path": "Extension.extension", "sliceName": "manufacturerModelName", "min": 0, "max": "1", "mustSupport": true }, { "id": "Extension.extension:manufacturerModelName.extension", "path": "Extension.extension.extension", "max": "0" }, { "id": "Extension.extension:manufacturerModelName.url", "path": "Extension.extension.url", "fixedUri": "manufacturerModelName" }, { "id": "Extension.extension:manufacturerModelName.value[x]", "path": "Extension.extension.value[x]", "type": [ { "code": "string" } ] }, { "id": "Extension.url", "path": "Extension.url", "fixedUri": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" }, { "id": "Extension.value[x]", "path": "Extension.value[x]", "max": "0" } ] } }
Beispiele
| Hinweis | |
|---|---|
|
|
Aus Gründen der Übersichtlichkeit wurde in diesem Beispiel darauf verzichtet, alle dazugehörigen Serien bzw. Instanzen mit einzubinden. Natürlich ist es bei der Implkementierung vorgesehen, dass alle zur jeweiligen Studie gehörenden Serien und Instanzen auch in der resultierenden FHIR-Ressource enthalten sind - dafür wird dann einfach die Sequenz "series" bzw "instance" für jede Serie bzw. Instanz wiederholt und mit den entsprechenden Werten befüllt. |
Beispiele von ImagingStudy-Ressourcen mit der Extension für die Angaben zum Gerät:
Beispiel eines CTs:
{ "resourceType": "ImagingStudy", "id": "mii-exa-bildgebung-bildgebungsstudie-ct", "meta": { "profile": [ "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-pr-bildgebung-bildgebungsstudie" ] }, "extension": [ { "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-bildgebungsgrund", "valueString": "Verdacht auf Karzinom" } ], "series": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "milligray", "value": 4.04 }, "url": "CTDIvol" }, { "valueQuantity": { "unit": "kilovolt", "value": 110 }, "url": "KVP" }, { "valueQuantity": { "unit": "milliampere second", "value": 38 }, "url": "exposure" }, { "valueQuantity": { "unit": "milliseconds", "value": 600 }, "url": "exposureTime" }, { "valueQuantity": { "unit": "milliampere", "value": 96 }, "url": "xRayTubeCurrent" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-modalitaet-ct" }, { "extension": [ { "url": "manufacturer", "valueString": "Beispielhersteller" }, { "url": "manufacturerModelName", "valueString": "Beispielmodell" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" }, { "extension": [ { "url": "contrastBolus", "valueBoolean": true }, { "url": "contrastBolusDetails", "valueReference": { "reference": "MedicationAdministration/mii-exa-bildgebung-kontrastmittelgabe" } } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-kontrastmittel" } ], "instance": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "millimeter", "value": 1.36 }, "url": "pixelSpacingX" }, { "valueQuantity": { "unit": "millimeter", "value": 1.36 }, "url": "pixelSpacingY" }, { "valueQuantity": { "unit": "millimeter", "value": 4 }, "url": "sliceThickness" }, { "url": "imageType", "valueString": "[DERIVED, PRIMARY]" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details" } ], "uid": "instance-example-uid", "sopClass": { "code": "urn:oid:1.2.840.10008.5.1.4.1.1.2", "system": "urn:ietf:rfc:3986" }, "number": 31 } ], "uid": "series-example-uid", "number": 1, "modality": { "code": "CT", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Computed Tomography" }, "description": "AC LD CT Whole Body 4.0 HD Field of View", "numberOfInstances": 195, "bodySite": { "code": "51185008", "system": "http://snomed.info/sct", "display": "Thoracic structure (body structure)" }, "laterality": { "code": "7771000", "system": "http://snomed.info/sct", "display": "Left" }, "started": "2024-07-19T12:03:30+02:00" } ], "status": "available", "modality": [ { "code": "CT", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Computed Tomography" } ], "subject": { "reference": "Patient/PatExample", "identifier": { "type": { "coding": [ { "code": "MR", "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "display": "Medical record number" } ] }, "system": "https://system-url", "value": "study-uid" } }, "encounter": { "reference": "Encounter/EncExample" }, "basedOn": [ { "reference": "ServiceRequest/mii-exa-bildgebung-anforderung-bildgebung" } ], "numberOfSeries": 2, "numberOfInstances": 390, "procedureReference": { "reference": "Procedure/mii-exa-bildgebung-bildgebungsprozedur" }, "reasonReference": [ { "reference": "Condition/CondExample" } ], "description": "whole body aquisition" }
Beispiel eines MRTs:
{ "resourceType": "ImagingStudy", "id": "mii-exa-bildgebung-bildgebungsstudie-mr", "meta": { "profile": [ "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-pr-bildgebung-bildgebungsstudie" ] }, "extension": [ { "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-bildgebungsgrund", "valueString": "Verdacht auf Kreuzbandruptur" } ], "series": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "tesla", "value": 3 }, "url": "magneticFieldStrength" }, { "url": "scanningSequence", "valueString": "SE" }, { "url": "scanningSequenceVariant", "valueString": "SP, SK" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-modalitaet-mr" }, { "extension": [ { "url": "manufacturer", "valueString": "Siemens Healthineers" }, { "url": "manufacturerModelName", "valueString": "MAGNETOM Vida" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" }, { "extension": [ { "url": "contrastBolus", "valueBoolean": false } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-kontrastmittel" } ], "instance": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "millimeter", "value": 0.260417 }, "url": "pixelSpacingX" }, { "valueQuantity": { "unit": "millimeter", "value": 0.260417 }, "url": "pixelSpacingY" }, { "valueQuantity": { "unit": "millimeter", "value": 3 }, "url": "sliceThickness" }, { "url": "imageType", "valueString": "[ORIGINAL, PRIMARY]" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details" } ], "uid": "instance-example-uid", "sopClass": { "code": "urn:oid:1.2.840.10008.5.1.4.1.1.4", "system": "urn:ietf:rfc:3986" }, "number": 28 } ], "uid": "series-example-uid", "number": 9, "modality": { "code": "MR", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Magnetic Resonance" }, "description": "pd_tse_sag", "numberOfInstances": 28, "bodySite": { "code": "72696002", "system": "http://snomed.info/sct", "display": "Knee region structure (body structure)" }, "laterality": { "code": "24028007", "system": "http://snomed.info/sct", "display": "Right" }, "started": "2024-07-19T12:03:30+02:00" } ], "status": "available", "modality": [ { "code": "MR", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Magnetic Resonance" } ], "subject": { "reference": "Patient/PatExample", "identifier": { "type": { "coding": [ { "code": "MR", "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "display": "Medical record number" } ] }, "system": "https://system-url", "value": "study-uid" } }, "encounter": { "reference": "Encounter/EncExample" }, "basedOn": [ { "reference": "ServiceRequest/mii-exa-bildgebung-anforderung-bildgebung" } ], "numberOfSeries": 11, "numberOfInstances": 294, "procedureReference": { "reference": "Procedure/mii-exa-bildgebung-bildgebungsprozedur" }, "reasonReference": [ { "reference": "Condition/CondExample" } ], "description": "Knie DOT" }
Beispiel eine Röntgenbilds:
{ "resourceType": "ImagingStudy", "id": "mii-exa-bildgebung-bildgebungsstudie-cr", "meta": { "profile": [ "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-pr-bildgebung-bildgebungsstudie" ] }, "extension": [ { "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-bildgebungsgrund", "valueString": "Verdacht auf Karzinom" } ], "series": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "kilovolt", "value": 110 }, "url": "KVP" }, { "valueQuantity": { "unit": "milliampere second", "value": 38 }, "url": "exposure" }, { "valueQuantity": { "unit": "milliseconds", "value": 600 }, "url": "exposureTime" }, { "valueQuantity": { "unit": "milliampere", "value": 96 }, "url": "xRayTubeCurrent" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-modalitaet-mg-cr-dx" }, { "extension": [ { "url": "manufacturer", "valueString": "SIEMENS" }, { "url": "manufacturerModelName", "valueString": "Fluorospot Compact FD" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" }, { "extension": [ { "url": "contrastBolus", "valueBoolean": false } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-kontrastmittel" } ], "instance": [ { "extension": [ { "extension": [ { "url": "imageType", "valueString": "[ORIGINAL,PRIMARY,RAD]" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details" } ], "uid": "instance-example-uid", "sopClass": { "code": "urn:oid:1.2.840.10008.5.1.4.1.1.1", "system": "urn:ietf:rfc:3986" }, "number": 1 } ], "uid": "series-example-uid", "number": 1, "modality": { "code": "CR", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Computed Radiography" }, "description": "X Thorax a.p. liegend", "numberOfInstances": 1, "bodySite": { "code": "43799004", "system": "http://snomed.info/sct", "display": "Thoracic structure (body structure)" }, "laterality": { "code": "66459002", "system": "http://snomed.info/sct", "display": "Unilateral" }, "started": "2024-07-19T12:03:30+02:00" } ], "status": "available", "modality": [ { "code": "CR", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Computed Radiography" } ], "subject": { "reference": "Patient/PatExample", "identifier": { "type": { "coding": [ { "code": "MR", "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "display": "Medical record number" } ] }, "system": "https://system-url", "value": "study-uid" } }, "encounter": { "reference": "Encounter/EncExample" }, "basedOn": [ { "reference": "ServiceRequest/mii-exa-bildgebung-anforderung-bildgebung" } ], "numberOfSeries": 1, "numberOfInstances": 1, "procedureReference": { "reference": "Procedure/mii-exa-bildgebung-bildgebungsprozedur" }, "reasonReference": [ { "reference": "Condition/CondExample" } ], "description": "Thorax auf Station;" }
Beispiel eines PET-Scans:
{ "resourceType": "ImagingStudy", "id": "mii-exa-bildgebung-bildgebungsstudie-pt", "meta": { "profile": [ "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-pr-bildgebung-bildgebungsstudie" ] }, "extension": [ { "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-bildgebungsgrund", "valueString": "Verdacht auf Karzinom" } ], "series": [ { "extension": [ { "extension": [ { "url": "radiopharmaceutical", "valueCodeableConcept": { "coding": [ { "code": "35321007", "system": "http://snomed.info/sct", "display": "Fluorodeoxyglucose (18-F) (substance)" } ] } }, { "url": "radiopharmaceuticalStartTime", "valueDateTime": "2024-07-19T12:03:30+02:00" }, { "url": "rescaleType", "valueString": "BQML" }, { "valueQuantity": { "unit": "Megabecquerel", "value": 196 }, "url": "radionuclideTotalDose" }, { "valueQuantity": { "unit": "Seconds", "value": 6586.2 }, "url": "radionuclideHalfLife" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-modalitaet-pt-nm" }, { "extension": [ { "url": "manufacturer", "valueString": "Beispielhersteller" }, { "url": "manufacturerModelName", "valueString": "Beispielmodell" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-geraet-hersteller" } ], "instance": [ { "extension": [ { "extension": [ { "valueQuantity": { "unit": "millimeter", "value": 2.89 }, "url": "pixelSpacingX" }, { "valueQuantity": { "unit": "millimeter", "value": 2.89 }, "url": "pixelSpacingY" }, { "valueQuantity": { "unit": "millimeter", "value": 4 }, "url": "sliceThickness" }, { "url": "imageType", "valueString": "['ORIGINAL', 'PRIMARY']" } ], "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details" } ], "uid": "instance-example-uid", "sopClass": { "code": "urn:oid:1.2.840.10008.5.1.4.1.1.128", "system": "urn:ietf:rfc:3986" }, "number": 31 } ], "uid": "series-example-uid", "number": 1, "modality": { "code": "PT", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Positron emission tomography" }, "description": "PET WB", "numberOfInstances": 195, "bodySite": { "code": "51185008", "system": "http://snomed.info/sct", "display": "Thoracic structure (body structure)" }, "laterality": { "code": "66459002", "system": "http://snomed.info/sct", "display": "Unilateral" }, "started": "2024-07-19T12:03:30+02:00" } ], "status": "available", "modality": [ { "code": "PT", "system": "http://dicom.nema.org/resources/ontology/DCM", "display": "Positron emission tomography" } ], "subject": { "reference": "Patient/PatExample", "identifier": { "type": { "coding": [ { "code": "MR", "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "display": "Medical record number" } ] }, "system": "https://system-url", "value": "study-uid" } }, "encounter": { "reference": "Encounter/EncExample" }, "basedOn": [ { "reference": "ServiceRequest/mii-exa-bildgebung-anforderung-bildgebung" } ], "numberOfSeries": 2, "numberOfInstances": 390, "procedureReference": { "reference": "Procedure/mii-exa-bildgebung-bildgebungsprozedur" }, "reasonReference": [ { "reference": "Condition/CondExample" } ], "description": "whole body aquisition" }