MII-Initiative

MII IG ICU v2025 - EN

Mean ventilation pressure (Observation)

Canonical: https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mittlerer-beatmungsdruck

"Mean ventilation pressure" is a characteristic of the generic profile for parameters of ventilation (Observation). See there for more information regarding explanations of the items, or reference of the entries in the FHIR resource to the Logical Model.

Differential

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
identifierS Σ0..*Identifier
basedOnΣ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
partOfS Σ1..1Reference(Procedure)
statusS Σ ?!1..1codeBinding
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uri
versionΣ0..1string
codeS Σ1..1code
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ1..1Reference(Patient | Device)
focusΣ0..*Reference(Resource)
encounterS Σ0..1Reference(Encounter)
effectiveDateTimedateTime
effectivePeriodPeriod
issuedS Σ0..1instant
performerΣ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam)
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ0..1string
systemS Σ I1..1uriPattern
codeS Σ1..1codePattern
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
note0..*Annotation
bodySite0..1CodeableConceptBinding
method0..1CodeableConcept
specimen0..1Reference(Specimen)
deviceS0..1Reference(SD_MII_ICU_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
age0..1Range
text0..1string
hasMemberΣ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)
derivedFromΣ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeΣ1..1CodeableConcept
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueBooleanboolean
valueIntegerinteger
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonI0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)


Snapshot

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
identifierS Σ0..*Identifier
basedOnΣ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
partOfS Σ1..1Reference(Procedure)
statusS Σ ?!1..1codeBinding
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uri
versionΣ0..1string
codeS Σ1..1code
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ1..1Reference(Patient | Device)
focusΣ0..*Reference(Resource)
encounterS Σ0..1Reference(Encounter)
effectiveDateTimedateTime
effectivePeriodPeriod
issuedS Σ0..1instant
performerΣ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam)
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ0..1string
systemS Σ I1..1uriPattern
codeS Σ1..1codePattern
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
note0..*Annotation
bodySite0..1CodeableConceptBinding
method0..1CodeableConcept
specimen0..1Reference(Specimen)
deviceS0..1Reference(SD_MII_ICU_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
age0..1Range
text0..1string
hasMemberΣ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)
derivedFromΣ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeΣ1..1CodeableConcept
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueBooleanboolean
valueIntegerinteger
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonI0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)

Beispiel

Eingestellt

{
    "resourceType": "Observation",
    "id": "exa-mii-icu-vent-mittlerer-beatmungsdruck-eingestellt",
    "meta": {
        "profile":  [
            "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mittlerer-beatmungsdruck"
        ]
    },
    "partOf":  [
        {
            "reference": "Procedure/example"
        }
    ],
    "status": "final",
    "category":  [
        {
            "coding":  [
                {
                    "system": "http://snomed.info/sct",
                    "code": "40617009",
                    "display": "Artificial ventilation (regime/therapy)",
                    "version": "http://snomed.info/sct/900000000000207008/version/20241101"
                }
            ]
        }
    ],
    "code": {
        "coding":  [
            {
                "system": "http://snomed.info/sct",
                "code": "698821009",
                "display": "Mean inspiratory airway pressure (observable entity)",
                "version": "http://snomed.info/sct/900000000000207008/version/20241101"
            },
            {
                "system": "http://loinc.org",
                "code": "76530-5",
                "display": "Mean pressure Respiratory system airway --on ventilator"
            },
            {
                "system": "urn:iso:std:iso:11073:10101",
                "code": "151975",
                "display": "Mean pressure Respiratory system airway --on ventilator"
            }
        ]
    },
    "subject": {
        "reference": "Patient/111"
    },
    "effectivePeriod": {
        "start": "12/23/2019 08:30:10",
        "end": "12/23/2019 09:30:10"
    },
    "valueQuantity": {
        "value": 15,
        "system": "http://unitsofmeasure.org",
        "code": "cm[H2O]"
    },
    "device": {
        "reference": "DeviceMetric/Example_Eingestellte_Parameter_Beatmung"
    }
}

Gemessen

{
    "resourceType": "Observation",
    "id": "exa-mii-icu-vent-mittlerer-beatmungsdruck-gemessen",
    "meta": {
        "profile":  [
            "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mittlerer-beatmungsdruck"
        ]
    },
    "partOf":  [
        {
            "reference": "Procedure/example"
        }
    ],
    "status": "final",
    "category":  [
        {
            "coding":  [
                {
                    "system": "http://snomed.info/sct",
                    "code": "40617009",
                    "display": "Artificial ventilation (regime/therapy)",
                    "version": "http://snomed.info/sct/900000000000207008/version/20241101"
                }
            ]
        }
    ],
    "code": {
        "coding":  [
            {
                "system": "http://snomed.info/sct",
                "code": "698821009",
                "display": "Mean inspiratory airway pressure (observable entity)",
                "version": "http://snomed.info/sct/900000000000207008/version/20241101"
            },
            {
                "system": "http://loinc.org",
                "code": "76530-5",
                "display": "Mean pressure Respiratory system airway --on ventilator"
            },
            {
                "system": "urn:iso:std:iso:11073:10101",
                "code": "151975",
                "display": "Mean pressure Respiratory system airway --on ventilator"
            }
        ]
    },
    "subject": {
        "reference": "Patient/111"
    },
    "effectivePeriod": {
        "start": "12/23/2019 08:30:10",
        "end": "12/23/2019 09:30:10"
    },
    "valueQuantity": {
        "value": 15,
        "system": "http://unitsofmeasure.org",
        "code": "cm[H2O]"
    },
    "device": {
        "reference": "DeviceMetric/Example_Gemessene_Parameter_Beatmung"
    }
}